100W-10kW Water-Cooled Laser Power Sensor
Product Features:
l Water Cooled
l Pyramidal structure
l 45mm Detector Aperture Size
l Ultra-high laser power
l Connect the USB Output Interface with PC Port
l Maximum continuous measurement power up to 10kW
Product Specifications:
Model | W10K-PT-45 |
Spectral range(μm) | 0.8 - 2, 10.6 |
Power range | 100W - 10kW |
Measurement Capability | |
Resolution(W) | 1 |
Measurement uncertainty(±%) | < 1 |
Nonlinearity with power(±%) | < 2 |
Power accuracy(±%) | < 5 |
Response time(S) | < 3 |
Detector type | PT |
Detector aperture(mm) | 45 |
Damage threshold | |
Maximum average power density | 3kW/cm2 |
Physical characteristics | |
Dimensions(mm) | Ф146 × 70 |
Cooling method | Water-Cooled |
Cooling water flow(L/min) | 8 - 10 |
Cable type | DB-9M |
Cable length(m) | 5 |
Product Dimensions:
Accessories:
Recommended products:
Model | Power range | Spectral range (μm) | Detector aperture (mm) | Features |
W5000-CB-55 | 20W-5000W | 0.19-25 | Φ55 | Water-Cooled 5000W continuous measurement |
100W-10kW Water-Cooled Laser Power Sensor
Product Features:
l Water Cooled
l Pyramidal structure
l 45mm Detector Aperture Size
l Ultra-high laser power
l Connect the USB Output Interface with PC Port
l Maximum continuous measurement power up to 10kW
Product Specifications:
Model | W10K-PT-45 |
Spectral range(μm) | 0.8 - 2, 10.6 |
Power range | 100W - 10kW |
Measurement Capability | |
Resolution(W) | 1 |
Measurement uncertainty(±%) | < 1 |
Nonlinearity with power(±%) | < 2 |
Power accuracy(±%) | < 5 |
Response time(S) | < 3 |
Detector type | PT |
Detector aperture(mm) | 45 |
Damage threshold | |
Maximum average power density | 3kW/cm2 |
Physical characteristics | |
Dimensions(mm) | Ф146 × 70 |
Cooling method | Water-Cooled |
Cooling water flow(L/min) | 8 - 10 |
Cable type | DB-9M |
Cable length(m) | 5 |
Product Dimensions:
Accessories:
Recommended products:
Model | Power range | Spectral range (μm) | Detector aperture (mm) | Features |
W5000-CB-55 | 20W-5000W | 0.19-25 | Φ55 | Water-Cooled 5000W continuous measurement |